Step by step to installing drywall partitions with the latest trends on how to install drywall with top tips from international designers, how to patch and repair drywall, drywall partitions of plasterboard and gypsum board with his hands
Often many of us in the repair have to build new interior walls. Someone makes them brick, and someone collects plywood. But why spend money on such expensive materials and do the dirty work when installing drywall partition walls with his own hands is much more practical? so I am writing this article for each person who asks How to drywall.
The matter is quite simple and dust-free - when working with drywall partition is the minimum of waste and construction debris, and to assemble the structure, then there really is no big deal, we need only to comply with mounting technology.
You can see also :
20 Decorative partition wall design and Wall paneling ideasTop shower tile ideas
![]() |
Installing drywall partition, how to drywall partition, plasterboard drywall |
how to Install drywall partition :
If you decide to seek help from a professional, you will have to pay quite a considerable sum, which is almost identical to the money spent on the building material.
It turns out that more profitable to invest in the more expensive and high-quality drywall partition materials and carry out the work with his own hands.
Types of drywall partition :
To date, the construction of three types of drywall partition are known:
Simple (this structure is a single layer of plasterboard and a simple framework);
Reinforced (metal frame covered with a double layer of drywall partition on each side);
The most powerful designs are a combination of reinforced metal frame and trim with a double layer of drywall partition on each side.
The choice of the type of gypsum board, as well as its quality, depends easy installing drywall partition and durability.
Attention! The amount could be higher, it all depends on the material (its value) that you choose and buy.
You can personally make sure that the figures are not drawn from the ceiling and you will not deceive.
Mount Technology for drywall partition :
Like any other mounted design, technology installation of plasterboard drywall partition has its own concepts and features :
- Mount the frame only after the preparation of all communications: Spend tube, mount, and connect the necessary wiring device (distribution box, sockets, switches, etc.).
- When installing drywall with a double (reinforced) frame must be between the profiles paste special soundproof sealing tape.
- Using a base frame made of timber you do not need to use the holes for the screws. Screws for wood do not need them.
- Pay attention to the fact that the height of the vertical profile (racks) must be less than the height of the ceiling by 10-15 mm.
- GCR is mounted first on one side, and after all the manipulations outlined below, on the other side of the drywall partition.
- Electrocable should be placed perpendicular to the studs.
- Thermal insulation is made only after all the work carried out on the installation of the electricity supply.
Installing drywall partitions of plasterboard was quick and without any problems, you need a reliable tool:
Drill or screwdriver (usually sold complete with bats, nozzles for screws)
Building a knife (for cutting GCR)
Punch
Plummet (marking)
Building levels
The marker or soft pencil
Plugs
Screws
Hammer
Roulette
Scissors on metal
Special reinforcing tape
Sheets of drywall
Polystyrene foam (the material used as the acoustic and thermal insulation).
So, here we are getting close to the subject - how to set the partition of the drywall. or how to drywall, To begin with, that all works are carried out in areas where the temperature is at least 10 ° C.
Now consider the stepwise assembly diagram :
- As with any other type of installing drywall, the installation of drywall partition begins with the markup.
![]() |
Installing drywall partition, how to drywall partition, plasterboard drywall |
![]() |
Installing drywall partition, how to drywall partition, plasterboard drywall |
The marks made on the floor, walls, and ceiling of course. The marking must clearly indicate the location of the future of doorways and pillars.
- After you mount the frame, you need to stick the front part of the profile strip, which will serve as good sound insulation. Alternatively, one can use an adhesive sealant.
- As mentioned earlier, under the framework of drywall you can install several ways: a double and a single.
![]() |
Installing drywall partition, how to drywall partition, plasterboard drywall |
As shown, the majority prefer to collect walls of the metal frame, rather than timber. The main reason - the low-cost metal profile:
- In general, the framework for collecting walls is made of 2-types of profiles and PN50 PS50 -guide and rack profile - The guides are mounted to the floor and ceiling with dowels. Rack profiles are installed perpendicular to the rails.
- As for fixing the guide profile - the maximum spacing between anchors should not exceed a distance of 1 m.
- Rack profiles are attached to the upper and lower rails, forming a coherent structure.
- The step between the posts - no more than 60 cm stand closer to each other, the stronger the structure. If you want to strengthen the framework, it is possible to put several racks on jumpers, securing them to the frame horizontally to liberate the uprights.
If the plasterboard drywall partition you plan to install the door , the door needs to be strengthened by means of installation of additional profile.
So, after we prepared a metal frame, you can safely proceed to the installation of the FCL:
- First, we need to relate the size of the sheets with height partitions. If something somewhere does not fit, use a knife and cut off the building's unnecessary items
![]() |
Installing drywall partition, how to drywall partition, plasterboard drywall |
Please note:
Cut the edges it is mandatory to handle them with sandpaper or a plane.
- To strengthen the angle design, you can use a special reinforcement tape, although the item cannot be considered binding.
- Place a sheet of drywall on the frame and press firmly. Then, armed with a screwdriver, begin to scroll it around the perimeter. Do not spare screws - the maximum spacing between them is not more than 25-30 cm.
- When tightening the screws required to heat a little heat into the material - about 1 mm.
- Do not forget about the gap between the floor and the sheet GCR (1-1.5 cm is sufficient).
- Now proceed to Electra accessories installation (sockets, switches). Their installation requires the use of special boxes, which will greatly facilitate your continued support (as in the case of a fault-replacement) of Electra accessories.
Top designs of drywall partition of plasterboard :
![]() |
Installing drywall partition, how to drywall partition, plasterboard drywall |
![]() |
Installing drywall partition, how to drywall partition, plasterboard drywall |
![]() |
Installing drywall partition, how to drywall partition, plasterboard drywall |
Now you know how to install drywall partitions. To more accurately understand the technological and practical issues our website provides detailed instruction photos in which you will easily find the necessary information on the matter. Good luck.